1. Take the valve (it is necessary to use a key 8.0117 АЕ for электрически operated valves Bosch). |
2. Measure resistance of an electromagnet (nearby 8 Ohm). If the measured value of resistance does not correspond to the aforesaid, it is necessary to replace the valve. |
3. Establish the valve supplied with a new round sealing ring, and tighten the moment of 15 Nanometers (Roto Diesel) or 20 Nanometers (Bosch). |
|