Peugeot405
1. The maintenance instruction
2. Maintenance service
3. Engines
    3.1. Petrol engines
    3.2. Diesel engines
      3.2.1. A technical characteristics
       3.2.2. Engine adjustments
      3.2.3. Removal and installation of the fuel pump of a high pressure
      3.2.4. Installation of the fuel pump of high pressure BOSCH
      3.2.5. Installation of the fuel pump of high pressure Roto Diesel
      3.2.6. Removal of water from the fuel filter
      3.2.7. Removal of air from fuel system
      3.2.8. Removal and atomizer installation
      3.2.9. Check электрически the operated valve of a stop of the engine
      3.2.10. Pump Bosch adjustment
      3.2.11. Pump Roto Diesel adjustment
      3.2.12. Removal and installation турбокомпрессора
       3.2.13. The repair which is not demanding removal of the engine
      3.2.14. Engine removal
      3.2.15. Engine installation
      3.2.16. Engine dismantling
      3.2.17. Engine assemblage
      3.2.18. The oil pump
       3.2.19. Cooling system
      3.2.20. System of release of the fulfilled gases
    3.3. The petrol engine 1,4 дм3
    3.4. Ignition system
4. Fuel system
5. Systems of greasing, cooling
6. Release system
7. Coupling
8. Transmissions
9. Power shafts
10. A steering
11. Suspension brackets
12. Brake system
13. A body
14. An electric equipment


3.2.6. Removal of water from the fuel filter
THE GENERAL DATA

SYSTEM OF INJECTION BOSСH, FILTER PURFLUX

System of injection Bosch with the filter and heater Purflux



1 – pipelines of injection,
2 – return pipelines,
3 – a bolt plum of water,
4 – the case,
5 – a filtering element,
6 – a thermostatic element,
7 – a head of the filter,
8 – the manual fuel pump

Fuel filter Purflux

1 – деаэратор,

2 – a bolt plum of water,

3 – the manual pump

PERFORMANCE ORDER
1. Open деаэратор (1).
2. Unscrew a bolt plum of water (2).
3. Merge water and pollution.
4. Screw up a bolt plum of water (2) and деаэратор (1).

SYSTEM OF INJECTION ROTO DIESEL

Fuel filter Roto Diesel

1 – деаэратор,

2 – a bolt plum of water,

3 – the manual pump

PERFORMANCE ORDER
1. Release a bolt plum of water (1).
2. Press the button (2) manual pumps for removal of water and pollution.