Peugeot405
1. The maintenance instruction
2. Maintenance service
3. Engines
4. Fuel system
5. Systems of greasing, cooling
6. Release system
7. Coupling
8. Transmissions
    8.1. A mechanical transmission
      8.1.1. A technical characteristics
      8.1.2. Oil replacement in a transmission
      8.1.3. Adjustment of draught of a gear change
      8.1.4. The gear change lever
      8.1.5. Draught of a gear change
      8.1.6. A cable of blocking of inclusion of a reverse gear
      8.1.7. Sealing rings
      8.1.8. The switch of a lantern of a backing
      8.1.9. A speedometer drive
      8.1.10. Removal and transmission installation
      8.1.11. Transmission dismantling
      8.1.12. Differential repair
      8.1.13. Repair of a primary shaft
      8.1.14. Repair of a secondary shaft
      8.1.15. Transmission assemblage
      8.1.16. Definition of a tightness of the conic bearing of a primary shaft
      8.1.17. The strengthened sealing rings
      8.1.18. Distinctive features of a drive 4 х 4
      8.1.19. A distributing box of system of a drive 4 х 4
    8.2. An automatic transmission
9. Power shafts
10. A steering
11. Suspension brackets
12. Brake system
13. A body
14. An electric equipment


8.1.8. The switch of a lantern of a backing
THE GENERAL DATA

The backing lantern joins the switch located in the top part картера of a transmission. Before check of the switch of a lantern of a backing to check up integrity of a safety lock in a feed circuit of a lantern of a backing.

Check

For switch check to disconnect an electric socket and, using an ohmmeter, to check up, whether switch contacts (resistance should be equal to zero) become isolated at reverse gear inclusion. Otherwise the switch is faulty and is subject to replacement.

Removal and installation

PERFORMANCE ORDER
1. For access improvement to the switch to remove tubes of giving of air in the engine, the accumulator and an accumulator support.
2. To disconnect an electric socket (it is specified стелкой), to unscrew the switch and to remove it together with a sealing ring.
3. Installation is made in sequence, return to removal.